AutoView 400 Installer/User Guide
Configure your terminal program to the following settings:
38,400 Baud
8 Bits
No Parity
1 Stop Bit
No Flow Control
Activate the OSD menu on your AutoView 400 by tapping the Control key
twice. Enter Control twice more to activate the Administrator Commands
screen and then select Administrator Functions.
Use the down arrow key to highlight the menu selection for FLASH Upgrade,
then hit Enter.
A menu screen will appear and ask if you wish to continue. You must type out
the word ‘Yes’ before proceding. Once you have done this, the AutoView
will go into a standby mode and wait for data from the computer. (Note: The
keyboard, video and mouse are disabled during the FLASH upgrade.)
The final step is to send the FLASH file from your terminal program. To do
this, you will need to use the transfer function of your communications
software. Send the FLASH file using the XMODEM protocol. The transfer
should be completed within four minutes.
The AutoView 400 will automatically check the upgrade and make sure that
it is valid. If the AutoView detects an error it will abort the upgrade and
prompt you to re-transfer the file. Otherwise, it will return the message
“Flash Upgrade Successful”.
40